Select Region

CLOSE MENU

Secure area

CLOSE MENU Login

Overview

Product images


Technical specification

 
Load cell spec
Units
Accuracy Class
3000*
n. OIML
Load Cell Capacity (Emax)
250, 500, 1000, 2000, 5000, 7500
kg
Rated Output (Sn)
2.0
mV/V ± 0.1 %**
Combined Error
< ± 0.017
% Sn
Non-repeatability
< ± 0.015
% Sn
Creep (30 minutes)
< ± 0.016
% Sn
Temperature Effect on Zero Balance
< ± 0.002
% Sn / ˚C
Temperature Effect on Span
< ± 0.0012
% Sn / ˚C
Compensated Temperature Range
-10 to +55
˚C
Operating Temperature Range
-40 to +95
˚C
Safe Overload
150
% Emax
Ultimate Overload
200
% Emax
Zero Balance
< ± 2

% Sn
Input Resistance
400
Ω ± 20
Output Resistance
350
Ω ± 3
Insulation Resistance
> 5000
MΩ @ 100V
Recommended Supply Voltage
5-15
V
Maximum Supply Voltage
15
V
Environmental Protection to EN 60529
IP68 / IP69K
-
Maximum deflection at Emax
0.2-0.4
mm
Cable Length
5
m
Cable Material
Polyurethane
-
Nominal Shipping Weight
(250-500kg, 1000-2000kg, 5000kg, 7500kg)

1, 2, 4, 5.5

kg

 

*for capacity range 500kg + 5000kg