Technical specification

 
Load cell spec
Units
Accuracy Class
3000*
n. OIML
Load Cell Capacity (Emax)
5, 10, 20, 30, 50,75, 100, 150, 200, 250, 300, 500
kg
Rated Output (Sn)
2
mV/V ± 0.1 %**
Combined Error
< ± 0.017
% Sn
Non-repeatability
< ± 0.015
% Sn

Minimum load cell verification
interval (vmin) = Emax / Y

Emax / 10000
kg
Creep (30 minutes)
< ± 0.016
% Sn
Temperature Effect on Zero Balance
< ± 0.002
% Sn / ˚C
Temperature Effect on Span
< ± 0.0012
% Sn / ˚C
Compensated Temperature Range
-10 to +40
˚C
Operating Temperature Range
-30 to +70
˚C
Safe Overload
200
% Emax
Ultimate Overload
300
% Emax
Zero Balance
< ± 2

% Sn
Input Resistance
400
Ω ± 20
Output Resistance
350
Ω ± 3
Insulation Resistance
> 5000
MΩ @ 100V
Recommended Supply Voltage
5-15
V
Maximum Supply Voltage
15
V
Environmental Protection
IP68 / IP69K
-
Maximum deflection at Emax
0.2-0.4
mm
Cable Length
3
m
Cable Material
Polyurethane
-
Nominal Shipping Weight
0.5
kg

*C3 as standard, C6 (6000 divisons) available to order at 50, 75, 100, 150, 200 & 250kg.

** For 5-20kg capacity range, rated output (Sn) tolerance is ± 0.2 %

Literature

LeverMount Lite Load Cell Literature

Levemount Lite Load Cell User Manual