Select Region

CLOSE MENU

Secure area

CLOSE MENU Login

Overview

Product images


Technical specification

 
Load cell spec
Units
Full Load Output
2.0
mV/V ± 0.25%
Excitation - Recommended
10
V
Excitation - Maximum
18
V
Safe Service Load
150
%*
Ultimate Overload
300
%*
Combined Error
< ± 0.03
%*
Repeatability
< ± 0.015
%*
Output at Zero Load
< ± 2.0
%*
Input Resistance
785
Ω ± 20
Output Resistance
705
Ω ± 5
Operational Temperature Range
-50 to +80
˚C
Compensated Temperature Range
-10 to +40
˚C
Temperature Coefficient on Zero
< ± 0.002
%* / ˚C
Temperature Coefficient on Span
< ± 0.0012
%* / ˚C
Environmental Protection
IP68 / IP69K
Cable Length
20
m
Cable Material
Polyurethane
Insulation
>5000
MΩ @ 100V

 

*All percentages are related to Full Rated Load

VC3500 combined error

Literature

VC3500 Load Cell Literature